M22520 series manual and pneumatic crimping tools are
widely used in crimping wires and terminals in electrical connectors. The
crimping pliers, if not used with the positioner, the operator will have to
determine the position of each crimping by eyes which will not only take
unnecessary time and effort, but also reduce the overall efficiency. Thus, the
positioner plays a very important role in the manual or pneumatic crimping
process.
Among all kinds of positioners, fixed positioners, screw-adjustable
positioners, turret positioners are the three main types. Screw-adjustable
positioner and turret positioner are more welcomed by the majority of customers
because of its wide range of application.
Proper installation and removal of the positioner are of
vital significance. Here we briefly introduce the installation and removal
steps of turret positioners.
Positioner: TH163 (M22520 / 1-04) Turret Positioner
Adaptation Tools: YJQ-W2A (M22520 / 1-01) Four-indent Crimping Pliers
Installation of
Positioner
1. With tool in open position, press positioner trigger
latch to release turret to indexing position
2. Place positioner onto retaining ring with alignment
pin in alignment hole
3. After positioner is seated against retainer ring,
tighten socket head screws with 9/64" hex
4. Press turret to check if it is installed correctly or
work proporly
5. With tool in open position, press positioner trigger
latch to release turret to indexing position again
6. Refer to dataplate on positioner. From color code
column, select the positioner color that corresponds with the appropriate part
number and size of contact to be crimped. Rotate until color coded insert is in
line with the index mark. Press turret until it snaps in latched position
Then, the installation process has been completed. Refer
to dataplate. From wire size column, determine the selector setting that
corresponds with the contact being used. Remove spring clip from selector knob
and rotate until correct setting is in line with selector mark. Next, the crimping
operation can be performed.
Removal of Positioner
With tool in open position, release turret. Loosen screws
until threads are disengaged from retainer ring and remove with a straight lifting
motion.
Caution: Tool
must be in open position whenever positioner is being installed, removed or
released. Damage to turret head and crimp tool may result if this procedure is
not followed.
Is the installation and removal process very simple?
没有评论: